LXW Series Hot-Water Boilers
Multiple water tube, Hot-water boiler. Miura’s Gas/Oil hot-water boiler is a low water content, water tube design, which provides full output within 5 minutes.
- Gas/Oil dual fuel burner
- Up to 300 BHP per boiler
|
SpecificationsNote
Specifications
| LXW-50G |
| Boiler Type |
Natural gas or Propane fired |
| Utilization Horsepower |
50 BHP |
| Maximum Pressure |
160 PSIG |
| Heat Output |
1,674,000 BTU/HR |
| Efficiency |
82% |
| Heating Surface Area |
176.5 FT² |
| Operational Weight |
3,200 LBS |
| Shipping Weight |
3,000 LBS |
| Width |
33 in. |
| Length |
81 in. |
| Height |
105 1/4 in. |
| Combustion System |
Proprietary forced draft, step fired modulation Hi-Low-Off |
| Ignition System |
Electric Spark Ignited, Interrupted Gas Pilot |
| Power Supply |
230, 460, or 575 V, 3 PHASE, 60 HZ |
| Max. Electrical Consumption |
3.7 KVA |
| Fuel Type |
Natural Gas or Propane (3-5 PSIG) |
| Gas Consumption |
2,030 SCFH |
| Gas Supply Pressure |
3-5 PSIG Natural Gas or Propane |
| Main Water Outlet |
3 in. |
| Safety Valve Outlet |
1 in. |
| Main Water Inlet |
3 in. |
| Fuel Gas Inlet |
1 1/2 in. |
| Manual Blowdown |
1 1/2 in. |
| Chimney Diameter (ID) |
12 in. |
| Flame Detector |
Ultraviolet Flame Eye Sensor |
| Overheat Protection |
Low water cut off and Thermocouple and Flow switch |
| Max. Water Temperature |
250°F |
| Full Water Content |
44 GAL |
| Temperature Control |
Adjustable Temperature Controllers |
Note
- Thermal efficiencies are based on high heating values of fuels at 140°F supply temperature water.
- UL and CGA/CSA approved for natural gas and propane.
- Gas consumption based on natural gas with high heating value of 1004 BTU/SCF.
- All Miura hot water boilers are fully packaged and test fired at the factory.
- Built to meet or exceed UL and ASME standards in U.S.A.; CGA/CSA and B-51 standards in Canada.
- 49 BHP units available on request.
|